Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Rev. 2.0 Page 1 of 5
Set your site on VICOR at vicorpower.com
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC converters.
This “junior” size complement to the higher power VI-200 family offers up to 100 W of isolated
and regulated power in a board mounted package. With thousands of input/output/power
combinations, and with a maximum operating temperature rating of 100˚C, the MiniMod
provides nearly unlimited flexibiliy for power system designers to meet demanding time to
market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an installed
base of over 8 million units, the MiniMod family combines state of the art power density with
the efficiency, low noise and reliability required by next generation power systems.
Features
RoHS compliant (VE versions)
Up to 50 Watts per cubic inch
cULus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
Isolated output
Data Sheet
VI-J00, VE-J00
Half Brick
DC-DC Converters
25 to 100 Watts
Low Line
Voltage 75% Transient[a] Vin 2 3.3 5 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95
Nom. (Range) Max Power Designators ZY0XWVTRM1P 2N3L JK4HFDB
12 (10-20) n/a 22 0XXYYYYYYXXXXXXXXXXXXXX
24 (10-36) n/a n/a V--YYYYYYYYYYYYYYYYY--------
24 (21-32) 18 36 1WWWWWWX XWWWWWWWWWWWWWW
24 (18-36) n/a n/a WWWWWWWX XWWWWWWWWWWWWWW
36 (21-56) 18 60 2Y Y Y Y Y Y Y Y X X X X X X X X X X X -- -- --
48 (42-60) 36 72 3WWWWWWX XWWWWWWWWWWWWWW
48 (36-76) n/a n/a NWW X X X X X X WWWWWWWWWWWWWW
72 (55-100) 45 110 4WWWWWWX XWWWWWWWWWWWWWW
110 (66-160) n/a n/a TWW X X X X X X WWWWWWWWWWWW -- --
150 (100-200) 85 215 5WWWWWWX XWWWWWWWWWWWWWW
150 (100-375) 170 425 7Y Y Y Y Y Y Y Y X X X X X X X X X X X -- -- --
300 (200-400) 90 n/a 6WWWWWWX XWWWWWWWWWWWWWW
VI J 6 1 C W
Family Series Input Output Grade Power
VI = Non-RoHS J=J00 0= 12 V N=48V Z=2V M=10V K=40V E= –10 to 100°C W= 100 W
VE = RoHS V= 24 V 4=72V Y= 3.3 V 1=12V 4=48V C= –25 to 100°C X= 75 W
1=24V T=110V 0=5V P= 13.8 V H=52V I= 40 to 100°C Y= 50 W
W=24V 5= 150 V X= 5.2 V 2=15V F=72V M= –55 to 100°C Z= 25 W
2=36V 6= 300 V W= 5.5 V N= 18.5 V D=85V
3=48V 7= 150/300 V V= 5.8 V 3=24V B=95V
T= 6.5 V L=28V
R= 7.5 V J=36V
Part Numbering
[a] Transient voltage for 1 second.
Vout Designators
Output
Input
Maximum Power Available for VI-Jxx-xx
Note: For additional packaging
options, please see page 4.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Rev. 2.0 Page 2 of 5
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Inrush charge 60x 10-6 60 x 10-6 100 x 10-6 Coulombs Nominal line
Input reflected 10% 10% IIN Nominal line, full load
ripple current – pp
Input ripple rejection
dB 120 Hz, nominal line
dB 2400 Hz, nominal line
No load power dissipation 1.35 2 1.35 2 Watts
25+20 Log
(
Vin
)
Vout
30+20 Log
(
Vin
)
Vout
20+20 Log
(
Vin
)
Vout
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Setpoint accuracy 1% 2% 0.5% 1% VNOM
Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load
1% 0.2% 0.5% VNOM LL to HL, No Load to 10%
Output temperature drift 0.02 0.01 0.02 % / °C Over rated temperature
Long term drift 0.02 0.02 %/1K hours
Output ripple – pp:
2 V, 3.3 V 200 100 150 mV 20 MHz bandwidth
5 V 5% 2% 3% VNOM 20 MHz bandwidth
10 – 48 V 3% 0.75% 1.5% VNOM 20 MHz bandwidth
Trim range
[a]
50% 110% 50% 110% VNOM
Total remote 0.5 0.5 Volts 0.25 V max. neg. leg
sense compensation
Current limit 105% 135% 105% 125% INOM Automatic restart
Short circuit current 105% 140% 105% 130% INOM
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Gate out impedance 50 50 Ohms
Gate in impedance 1000 1000 Ohms
Gate in high threshold 6 6 Volts Use open collector
Gate in low threshold 0.65 0.65 Volts
Gate in low current 6 6 mA
[a] 10 V, 12 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
95 V output –50 + 0% trim range.
INPUT SPECIFICATIONS
OUTPUT CHARACTERISTICS
CONTROL PIN SPECIFICATIONS
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Rev. 2.0 Page 3 of 5
Set your site on VICOR at vicorpower.com
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Input to output 3,000 3,000 VRMS Baseplate earthed
Output to baseplate 500 500 VRMS
Input to baseplate 1,500 1,500 VRMS
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Efficiency 78 – 88% 80 – 90%
Baseplate to sink 0.14 0.14 °C/Watt With Vicor P/N 20267
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Weight 2.9 3.2 3.6 3.4 3.8 4.1 Ounces
82.8 92 101.2 96.3 107 117.7 Grams
DIELECTRIC WITHSTAND CHARACTERISTICS
THERMAL CHARACTERISTICS
MECHANICAL SPECIFICATIONS
Parameter Storage Operating Units Notes
E -20 to +105 -10 to + 100 °C
C -40 to +105 -25 to + 100 °C
I -55 to +105 -40 to + 100 °C
M -65 to +105 -55 to + 100 °C
PRODUCT GRADE TEMPERATURES
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Rev. 2.0 Page 4 of 5
Set your site on VICOR at vicorpower.com
MECHANICAL DRAWING
5
6
7
8
9
4
3
2
1
0.080 Dia (2) places 0.080 Dia (2) places
Solder plate Matte tin over copper
over copper alloy alloy
0.040 (1,0) Dia (7) places 0.040 Dia (7) places
Matte tin over copper
Solder plate
over copper alloy alloy
.01
Aluminum Base
Product ID
this surface
Function
+In
-In
+Out
Trim
–Sense
–Out
Pin #
1
2
3
4
5
6
7
8
9
FULL R
+.030 (0,76)
-.000 (0)
(5,6) Min.
(7,6) Min. (44,4) Max.
(61,0)
(57,9)
(3,0)
(12,7)
1.90
.65
(16,5)
.49
(12,4)
.30±.015
(7,6)±(0,38)
.15
2.10
(53,4)
(33,0)
.40
(10,2)
.35± .015
(8,9)±(0,38)
1.40
(35,6)
1.00
(25,4)
.70
(17,8)
Gate In
Gate Out
+Sense
VI-J00
2.28
1.30
(3,8) .15
(3,8)
(48,3)
.22
.12
.50
.30
2.40
1.75
Standard RoHS
Standard RoHS
Flangeless package Flangeless package
with integral heat sink
To order the SlimMod configuration add the suffix “ S” to
the standard module part number.
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Available with longitudinal or transverse fins of 0.25" or
0.50" height. Add the appropriate suffix to the module
part number.
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
To order the BusMod fully assembled, add suffix “–B1” to
the standard module part number.
To order the BusMod separately:
Half-sized BusMod — P/N 18952
2.28"L x 1.80"W x 0.50"H
(57,9 x 45,7 x 12,7 mm)
Longitudinal, 0.25" fins — add suffix “–F1”
Longitudinal, 0.50" fins — add suffix “–F2”
Transverse, 0.25" fins — add suffix “– F3”
Transverse, 0.50" fins — add suffix “– F4”
PACKAGING OPTIONS
2.28"L x 2.40"W x 1.08"H
(57,9 x 61,0 x 27,4 mm)
1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7 mm)
2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7 mm)
3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7 mm)
MegaMod Jr.
Chassis mount alternatives, one, two,
or three outputs: up to 300 W
BusMod
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Rev. 2.0 3/09
Set your site on VICOR at vicorpower.com
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC
modules and accessory components, fully configurable AC-DC and DC-DC power supplies,
and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned
without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed
for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function,
or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con-
vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo-
nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and
Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor
against all damages.