50 USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662
SPECIAL FEATURES
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense & remote inhibit
• Power fail
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 2 Supervisory outputs 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Optional top with fan cover -CF
• Optional end fan cover -CEF
ENVIRONMENTAL
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
ELECTRICAL SPECIFICATIONS
Input
Input range ........................... 85-264 V AC; 120-370 VDC
Frequency ............................ 47-440 Hz
Inrush current.......................20 A max., cold start @ 25°C
Efficiency.............................. 75% typical at full load
EMI filter ............................... FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and
radiated
Power factor ......................... 0.99 typical
Safety ground
leakage current .................... <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power................... With cover: 250 W with 30 CFM forced air .
(-C) (-CF) (CEF)
Adjustment range ................. ±5% minimum
Supervisory output ............... 5 V @ 100 mA regulated; 12V @ 500 mA
Hold-up time......................... 20 ms @ 250 W load, 115 VAC nominal line
Overload protection.............. Short circuit protection on all outputs. Case
overload protected @ 110-145% above
peak rating
Overvoltage protection ......... 5 V output: 5.7 to 6.7 VDC. Other outputs
10% to 25% above nominal output
Logic Control
Power failure ........................ TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4 msec
before loss of regulation
Remote on/off....................... Requires an external contact (N.O or N.C)
to inhibit outputs
DC OK.................................. TTL logic goes high 50-50 msec after the
output. It goes low when there is loss of
regulation.
Remote sense ...................... Compensates for 0.5 V lead drop min. Will
operate without remote sense connected.
Reverse connection protected.
SAFETY
VDE0805/EN60950 (IEC950) 11774-3336-1262
ULUL1950E132002
CSACSA 22.2-234 Level 5LR53982C
NEMKOEN 60950/EMKO-TUEP95103843
(74-sec) 203
BABTEN60950/BS7002PS/606027
CB Certificate and report 2241
CE Mark (LVD)
LPS 250
250 Watts
Total Power
200 - 250 Watts
Input Voltages
85 - 264 VAC
120 - 370 VDC
LPS 250 Series
# of Outputs
Single