For more Information
please call
1-800-Belden1
General Description:
16 AWG triads stranded (7x24) bare copper conductors, twisted triads, overall Beldfoil shield (100%
coverage), PVC insulation, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors # Triads AWG Stranding Conductor Material
1 1 16 7x24 BC - Bare Copper
Total Number of Conductors: 3
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.406
Inner Shield
Inner Shield Color Code Chart:
Number Color
1Black & Red & White and Numbered
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
18 7x26 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.940
Outer Jacket Ripcord: Yes
Overall Cable
Overall Nominal Diameter: 6.883 mm
Pair
Pair Lay Length & Direction:
Twists (twist/m)
6
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +105°C
Bulk Cable Weight: 86.762 Kg/Km
Max. Recommended Pulling Tension: 271.340 N
Min. Bend Radius/Minor Axis: 68.580 mm
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1031A Triad - 300V Power-Limited Tray Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG, ITC, PLTC
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2464 (300 V 80°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
CSA Flame Test: FT4
IEEE Flame Test: 1202
Suitability
Suitability - Burial: Yes
Sunlight Resistance: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.511836
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
177.502
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
319.241
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
12.1397
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
16.0769
Max. Operating Voltage - UL:
Voltage
300 V RMS
Notes (Overall)
Notes: Alternate color coding available upon request.
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1031A Triad - 300V Power-Limited Tray Cable
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1031A 0061000 305 MT 25.855 KG BLUE, LIGHT C 3 #16 PVC FS PVC
1031A 00610000 3,048 MT 267.621 KG BLUE, LIGHT C 3 #16 PVC FS PVC
1031A 0101000 305 MT 26.308 KG BLACK C 3 #16 PVC FS PVC
1031A 01010000 3,048 MT 272.157 KG BLACK C Z 3 #16 PVC FS PVC
1031A 0105000 1,524 MT 129.274 KG BLACK C Z 3 #16 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 2 Revision Date: 07-30-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1031A Triad - 300V Power-Limited Tray Cable