www.recom-power.com REV.: 9/2018 PA-4
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)
RAC03-SE/277
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment - General Requirments for Safety (CB Scheme) L0339L26-CB-1-B4
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety E224736-A24-UL UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 60950-1, 2nd Edition, 2014
Household and similar electrical appliances - Safety - Part 1: General requirements
L0339L26-B2-L EN60335-1:2012 + A11:2014
EAC Safety of Low Voltage Equipment RU-AT.49.09571 TP TC 004/2011
RoHS2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Industrial) Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements
1502CE17
Information technology equipment - Immunity characteristics - Limits and methods
of measurement EN55024:2010
ESD Electrostatic discharge immunity test ±8.0kV air, ±4.0kV contact
EN61000-4-2:2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV EN61000-4-4:2012, Criteria A
Power Magnetic Field Immunity 50Hz, 1A/m EN61000-4-8:2010, Criteria A
Voltage Dips and Interruptions
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria B
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
EMC Compliance (Household) Condition Standard / Criterion
Electromagnetic compatibility - Requirements for household appliances, electric
tools and similar apparatus - Part 1: Emission E16113001
EN55014-1:2006+A2:2011
Information technology equipment - Immunity characteristics - Limits and methods
of measurement EN55014-2:2015
ESD Electrostatic discharge immunity test ±8.0kV air, ±4.0kV contact IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV
DC Output: ±0.5kV IEC61000-4-4:2012, Criteria A
Surge Immunity AC Power Port:L to N ±2.0kV
DC Output: L to N ±1.0kV IEC61000-4-5:2014, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
3 Vr.m.s. IEC61000-4-6:2013, Criteria A
Voltage Dips and Interruptions
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
IEC61000-4-11:2004, Criteria B
IEC61000-4-11:2004, Criteria C
IEC61000-4-11:2004, Criteria C
Limits of Harmonic Current Emissions EN61000-3-2:2014
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material case
potting
silicone, (UL94V-0)
Dimension (LxWxH) 38.25 x 24.35 x 17.4mm
Weight 28g typ.
continued on next page