For more Information
please call
1-800-Belden1
General Description:
22 AWG solid bare copper conductors, FRFPE insulation, Beldfoil® (100% coverage) plus a tinned copper
braid shield (65% coverage), sunlight resistant PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
122 Solid BC - Bare Copper .026
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material
FRFPE - Flame Retardant Foam Polyethylene
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Beldfoil® Tape Aluminum Foil-Polyester Tape 100
2 Braid TC - Tinned Copper 65
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 0.315 in.
Pair
Pair Color Code Chart:
Number Color
1Red & Green
Pair Lay Length & Direction:
Lay Length (in.)
2.750
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +75°C
UL Temperature Rating: 60°C
Bulk Cable Weight: 52 lbs/1000 ft.
Max. Recommended Pulling Tension: 50 lbs.
Min. Bend Radius/Minor Axis: 3.200 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG, PLTC
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 20201 (600 V 75°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
Page 1 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3079A Multi-Conductor - DataBus® ISA/SP-50 PROFIBUS Cable
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
CSA Flame Test: FT4
IEEE Flame Test: 1202
Suitability
Sunlight Resistance: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.282
Nom. Mutual Capacitance:
Capacitance (pF/ft)
8.5
Nominal Velocity of Propagation:
VP (%)
78
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
16.0
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 3.900 Ohm/1000 ft
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
0.200 0.270
4.000 0.670
16.000 1.370
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100 m)
0.200 1.100
4.000 2.650
16.000 5.400
Max. Operating Voltage - UL:
Voltage
300 V RMS (NEC Type CMG)
600 V RMS (UL AWM Style 20201)
300V RMS (NEC Type PLTC)
Max. Recommended Current:
Description Current
Per Conductor 2.3 Amps
Other Electrical Characteristic 1: Capacitance Unbalance @ 1 kHz: Less than 1000 pF/km
Other Electrical Characteristic 2: Input Impedance/Unfitted Impedance 3 - 20 MHZ, 150 +-15 Ohms
Notes (Overall)
Notes: Siemens Sinec L2 Cable. For CPE jacketed version order Part No. YR45047. For LS0H (FRNC) jacketed version, order Part No. YR44731.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
3079A 0071000 1,000 FT 56.000 LB VIOLET C 1 PR #22 FRFPE FRPE SH PVC
3079A 0072000 2,000 FT 112.000 LB VIOLET C 1 PR #22 FRFPE FRPE SH PVC
3079A 0073600 3,600 FT 201.600 LB VIOLET C 1 PR #22 FRFPE FRPE SH PVC
3079A 0075000 5,000 FT 285.000 LB VIOLET 1 PR #22 FRFPE FRPE SH PVC
3079A 0601000 1,000 FT 56.000 LB CHROME C 1 PR #22 FRFPE FRPE SH PVC
Page 2 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3079A Multi-Conductor - DataBus® ISA/SP-50 PROFIBUS Cable
3079A 0602000 2,000 FT 112.000 LB CHROME C 1 PR #22 FRFPE FRPE SH PVC
3079A 0603600 3,600 FT 201.600 LB CHROME C 1 PR #22 FRFPE FRPE SH PVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 4 Revision Date: 12-18-2013
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3079A Multi-Conductor - DataBus® ISA/SP-50 PROFIBUS Cable