Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Reverse Current 15mA
Forward Current 10mA
Storage Temperature −60˚C to +150˚C
Operating Temperature Range (Note 2)
LM136-5.0 −55˚C to +150˚C
LM236-5.0 −25˚C to +85˚C
LM336-5.0 0˚C to +70˚C
Soldering Information
TO-92 Package (10 sec.) 260˚C
TO-46 Package (10 sec.) 300˚C
SO Package
Vapor Phase (60 sec.) 215˚C
Infrared (15 sec.) 220˚C
See AN-450 “Surface Mounting Methods and Their Effect on
Product Reliability” (appendix D) for other methods of sol-
dering surface mount devices.
Electrical Characteristics
(Note 3)
LM136A-5.0/LM236A-5.0 LM336B-5.0
Parameter Conditions LM136-5.0/LM236-5.0 LM336-5.0 Units
Min Typ Max Min Typ Max
Reverse Breakdown Voltage T
A
=25˚C, I
R
=1 mA
LM136-5.0/LM236-5.0/LM336-5.0 4.9 5.00 5.1 4.8 5.00 5.2 V
LM136A-5.0/LM236A-5.0, LM336B-5.0 4.95 5.00 5.05 4.90 5.00 5.1 V
Reverse Breakdown Change T
A
=25˚C, 6 12 6 20 mV
With Current 600 µA≤I
R
≤10 mA
Reverse Dynamic Impedance T
A
=25˚C, I
R
=1 mA, f = 100 Hz 0.6 1.2 0.6 2 Ω
Temperature Stability V
R
Adjusted 5.00V
(Note 4) I
R
=1 mA, (Figure 2)
0˚C≤T
A
≤70˚C (LM336-5.0) 4 12 mV
−25˚C≤T
A
≤+85˚C (LM236-5.0) 7 18 mV
−55˚C≤T
A
≤+125˚C (LM136-5.0) 20 36 mV
Reverse Breakdown Change 600 µA≤I
R
≤10 mA 6 17 6 24 mV
With Current
Adjustment Range Circuit of Figure 1 ±1±1V
Reverse Dynamic Impedance I
R
= 1 mA 0.8 1.6 0.8 2.5 Ω
Long Term Stability T
A
=25˚C±0.1˚C, I
R
=1 mA, t = 1000 hrs 20 20 ppm
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Electrical specifications do not apply when operating the device
beyond its specified operating conditions.
Note 2: For elevated temperature operation, Tjmax is:
LM136 150˚C
LM236 125˚C
LM336 100˚C
Thermal Resistance TO-92 TO-46 SO-8
θ
ja
(Junction to Ambient) 180˚C/W (0.4" Leads) 440˚C/W 165˚C/W
170˚C/W (0.125"
Leads)
θ
ja
(Junction to Case) N/A 80˚C/W N/A
Note 3: Unless otherwise specified, the LM136-5.0 is specified from −55˚C≤TA≤+125˚C, the LM236-5.0 from −25˚C≤TA≤+85˚C and the LM336-5.0 from
0˚C≤TA≤+70˚C.
Note 4: Temperature stability for the LM336 and LM236 family is guaranteed by design. Design limits are guaranteed (but not 100% percent production tested) over
the indicated temperature and supply voltage ranges. These limits are not used to calculate outgoing quality levels. Stability is defined as the maximum charge in
VREF from 25˚C to TA(min) or TA(max).
LM136-5.0/LM236-5.0/LM336-5.0
www.national.com3