Output - All Models (continued)
12 V Outputs (Payload Power)1,2
Management Power Interdependence 12 V will not be applied without
3.3 V applied to a load
Removal of 3.3 V also removes 12 V
and de-asserts ENABLE#
Setpoint 12.6 Vdc typical
11.8 Vdc typical
Configured as Primary PM
Configured as Redundant PM
Total Regulation Range 12.25 to 12.95 Vdc
11.60 to 12.00 Vdc
Configured as Rrimary PM
Configured as Redundant PM
Rated Load 600 W maximum
80 W / 7.6 A maximum
Per Power Module, input voltage ≥110 Vac
Per load channel
Minimum Load No load No loss of regulation ≥110 Vrms
Output Rise TIme (per channel) 25 ms maximum With 1600 μF on output under test
Output Noise (PARD)375 mV maximum
100 mV maximum
0 to 30 MHz
0 to 100 MHz
Output Voltage Overshoot 2% maximum Referenced to setpoint
Transient Response 3% maximum deviation
2 ms recovery time
2 A loadstep @ 1 A/μs
Referenced to load current and setpoint at
onset of transient. Recovery time to within 1%
of setpoint at onset of transient
Voltage Sag 1.00 V maximum Primary PM to redundant PM transition with
maximum of 80 W load per output or 600 W
load per PM
Short Circuit Protection 9.7 A maximum
10 ms maximum
Output to return
Channel Fault Operation
(Output to Return)
12V Payload Power Output under fault is
shutdown. 3V3 MP on the same channel
is not affected. The other channels are not
affected
After removal of fault, the output channel is
available again under control of the Carrier
Manager. PM_OK# is not de-asserted and
redundant failover is not initiated
Channel Fault Operation
(Output to Output)
No damage to Power Module Either or both outputs may
shut down until fault is removed
PS1# Extraction Delay 100 μs maximum Time from de-assertion of PS1# to disabling of
the channel outputs and de-assertion of the
ENABLE# signal
Reflected Ripple Tolerance on
Cooling Unit Outputs4
100 mV pk-pk
0.8 A pk-pk
Tolerance of Power Module to ripple generated
by fans or motors connected to Payload Power
on Cooling Units
Embedded Power for
Business-Critical Continuity
Rev. 05.26.08
MTC600 Series
4 of 19
Note 1: All channels and outputs must be confi gued by the carrier manager with the exception of MCH and CU channels and outputs
which are confi gured during Startup and/or autonomous operation,
Note 2: All measurements are made at the output connector of the Power Module. Unless otherwise specifi ed,specs apply to all AMC,
MCH, and CU outputs.
Note 3: Measured with a 0.1 μF ceramic and 10 μF tantalum capacitor on any output and oscilloscope bandwidth set for 200 MHz.
Note 4: Consult with the factory if other outputs are expected to product signifi cant ripple current.
Electrical Specifications (continued)