EURO/IEC Fuses & Accessories gF, gI-gG, aM CYLINDRICAL FUSE-LINKS DOMESTIC AND INDUSTRIAL CYLINDRICAL FUSE-LINKS Ferraz Shawmut gF, gI-gG and aM fuse-links cover a wide range of physical sizes and ampere ratings for 250, 400, 500, and 690 volts AC. gF fuse-links are for domestic use. gI-gG and aM fuse-links are for industrial applications. Most ratings are available with an optional indicator. All industrial fuse-links have the option of a built-in striker. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. gF gI-gG gI-gG aM FULL RANGE PROTECTION FULL RANGE PROTECTION FULL RANGE PROTECTION SHORT CIRCUIT PROTECTION 7 physical sizes from 6.3 x 23mm to 10.3 x 38 mm 4 physical sizes from 8 x 31mm to 22 x 58 mm Fuse-links with Striker 4 physical sizes from 8 x 31mm to 22 x 58mm 250 and 400 Volt ratings 0.5A through 32A 400, 500 and 690 Volt ratings - 0.5A through 125A Most ratings available with indicator Most ratings available with indicator 400, 500 and 690 Volt ratings 4A through 125A Meet IEC, NFC, UNE and British standards Meet IEC, NFC and UNE standards All ratings include striker Approved by Lloyds Register of Shipping and Bureau Veritas Meet IEC, NFC and UNE standards 2 sizes14 x 51mm and 22 x 58mm Approved by Lloyds Register of Shipping and Bureau Veritas F2 400, 500 and 690 Volt ratings - .16A through 125A Most ratings available with indicator Meet IEC, NFC and UNE standards Approved by Lloyds Register of Shipping and Bureau Veritas aM SHORT CIRCUIT PROTECTION Fuse-links with Striker 2 sizes 14 x 51mm and 22 x 58mm 400, 500 and 690 Volt ratings 2A through 125A All ratings include striker Meet IEC, NFC and UNE standards Approved by Lloyds Register of Shipping and Bureau Veritas EURO/IEC Fuses & Accessories gF CYLINDRICAL FUSE-LINKS Catalog Numbers, Ratings - gF (Optional Blown-Fuse Indicator) SIZE (mm x mm) RATED In CURRENT (A) RATED VOLTAGE 2 4 6 10 250V 10013-G 10019-G 10023-G 10031-G 250V 8.5 X 23 2 4 6 10 16 10.3 X 25.8 6 10 16 8.5 x 31.5 6.3 x 23 10031-G 10235-G 10637-G CATALOG NUMBER w/o Indicator w/Indicator INTERRUPTING RATING (A) STANDARD PACK/CTN. - 6,000 10/100 10213-G 10219-G 10223-G 10231-G 10235-G 12213-G 12219-G 12223-G 12231-G 12235-G 6,000 10/100 250V 10423-G 10431-G 10435-G 12423-G 12431-G 12435-G 6,000 10/100 0.5 1 2 4 6 8 10 12 16 20 25 400V 10609-G 10611-G 10613-G 10619-G 10623-G 10627-G 10631-G 10633-G 10635-G 10637-G 10639-G 12609-G 12611-G 12613-G 12619-G 12623-G 12627-G 12631-G 12633-G 12635-G 12637-G 12639-G 20,000 10/100 16 20 25 400V 10835-G 10837-G 10839-G 12835-G 12837-G 12839-G 20,000 10/100 2 4 6 10 16 20 25 32 400V 11013-G 11019-G 11023-G 11031-G 11035-G 11037-G 11039-G 11043-G 13013-G 13019-G 13023-G 13031-G 13035-G 13037-G 13039-G 13043-G 20,000 10/100 25 32 400V 11239-G 11243-G 13239-G 13243-G 20,000 10/100 F 10839-G 10.3 x 31.5 11035-G 8.5 x 36 10.3 x 38 11243-G 1 2 3 4 5 6 7 Ceramic body Sand Indicator contact Lower contact Contact ring Melting element Indicator Dimensions FUSE SIZE (mm x mm) A B C 6.3 X 23 8.5 X 23 10.3 x 25.8 8.5 x 31.5 10.3 x 31.5 8.5 x 36 10.3 x 38 6.3 8.5 10.3 8.5 10.3 8.5 10.3 23 23 25.8 31.5 31.5 36 38 5 5 6.3 6.3 10 6.3 10 F3 Blown-Fuse Indicator BEFORE AFTER EURO/IEC Fuses & Accessories gF CYLINDRICAL FUSE-LINKS Time in Seconds Melting Time - Current Data - 2-16 Amperes, 250V Time in Seconds Melting Time - Current Data - 2-32 Amperes, 400V Current in Amperes Current in Amperes F4 EURO/IEC Fuses & Accessories gI-gG CYLINDRICAL FUSE-LINKS Catalog Numbers, Ratings - gI-gG (Optional Blown-Fuse Indicator) SIZE (mm x mm) 15037-G 8 x 31 16037-G 10 X 38 14 X 51 17039-G 22 x 58 18059-G RATED In CURRENT (A) RATED VOLTAGE 0.5 1 2 4 6 8 10 12 16 20 400V 0.5 1 2 4 6 8 10 12 16 20 25 32 500V 400V 1 2 4 6 8 10 12 16 20 25 32 40 50 690V 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 690V 500V 400V 500V 400V CATALOG NUMBER w/o Indicator w/Indicator INTERRUPTING RATING (A) 15009-G 15011-G 15013-G 15019-G 15023-G 15027-G 15031-G 15033-G 15035-G 15037-G 15211-G 15213-G 15219-G 15223-G 15227-G 15231-G 15233-G 15235-G 15237-G 20,000 16009-G 16011-G 16013-G 16019-G 16023-G 16027-G 16031-G 16033-G 16035-G 16037-G 16039-G 16043-G 16213-G 16219-G 16223-G 16227-G 16231-G 16233-G 16235-G 16237-G 16239-G 16243-G 120,000 17011-G 17013-G 17019-G 17023-G 17027-G 17031-G 17033-G 17035-G 17037-G 17039-G 17043-G 17047-G 17051-G 17213-G 17219-G 17223-G 17227-G 17231-G 17233-G 17235-G 17237-G 17239-G 17243-G 17247-G 17251-G 80,000 18013-G 18019-G 18023-G 18027-G 18031-G 18033-G 18035-G 18037-G 18039-G 18043-G 18047-G 18051-G 18055-G 18059-G 18063-G 18065-G 18219-G 18223-G 18227-G 18231-G 18233-G 18235-G 18237-G 18239-G 18243-G 18247-G 18251-G 18255-G 18259-G 18263-G 18265-G STANDARD PACK/CTN. 10/100 10/100 F 10/50 120,000 80,000 10/50 120,000 Blown-Fuse Indicator Dimensions BEFORE AFTER F5 FUSE SIZE A B C 8 x 31 10 x 38 14 x 51 22 x 58 8.5 10.3 14.3 22.2 31.5 38 51 58 6.3 10.5 13.8 16.2 EURO/IEC Fuses & Accessories gI-gG CYLINDRICAL FUSE-LINKS Catalog Numbers, Ratings - gI-gG with Striker SIZE (mm x mm) 17447-G RATED CURRENT In RATED VOLTAGE CATALOG NUMBER INTERRUPTING RATING (A) 2 4 6 8 10 12 16 20 25 32 40 50 500V 17413-G 17419-G 17423-G 17427-G 17431-G 17433-G 17435-G 17437-G 17439-G 17443-G 17447-G 17451-G 120,000 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 690V 18419-G 18423-G 18427-G 18431-G 18433-G 18435-G 18437-G 18439-G 18443-G 18447-G 18451-G 18455-G 18459-G 18463-G 18465-G 80,000 STANDARD PACK/CTN. (A) 18447-G Striker 14 X 51 BEFORE 1 2 3 4 5 6 7 400V 10/50 AFTER Ceramic body Sand Indicator contact Lower contact Contact ring Melting element Indicator 22 X 58 500V 400V 10/50 120,000 Dimensions FUSE SIZE A B C D E 14 x 51 22 x 58 14.3 22.2 51 58 13.8 16.2 7.5 7.5 3.8 3.8 Melting Time - Current Data - 2-125 Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data - 2-125 Amperes Available Current in RMS Symmetrical Amperes Current in Amperes F6 EURO/IEC Fuses & Accessories gI-gG CYLINDRICAL FUSE-LINKS I2t Characteristics - Discrimination I2t (Ampere2 Seconds) Power Loss (Watts) at Rated Current In RATED CURRENT (A) SIZE 10 x 38 1 0.27 W 2 0.4 W 4 0.60 W 0.7 W 6 0.85 W 1.0 W 1.3 W 8 1.0 W 1.3 W 1.45 W 10 1.2 W 1.5 W 1.85 W 12 1.4 W 1.7 W 2.2 W 16 1.6 W 2.0 W 2.3 W 20 1.9 W 2.3 W 2.65 W 25 2.3 W 2.7 W 3.1 W 32 2.9 W 3.3 W 3.85 W 14 x 51 0.5 W 4W 4.8 W 50 4.5 W 5.3 W 6.5 W 80 8W 100 9W 125 12.5 W IEC 269-2 _ _ _ _ _ 690V _ _ _ _ _ 500V _ _ _ _ _ 400V 0.9 W 40 63 Fuse-link In (A) 22 x 58 10 x 38 14 x 51 22 x 58 NFC 63210 25A 40A 100A UBE 21103 3W 5W 9.5 W These values are much lower than those allowed by the standards. Operating I2t _ _ _ _ _ Pre-arcing I2t Temperature Temperature rise reached by gI-gG fuse-links at In, measured on their upper contact. F7 F EURO/IEC Fuses & Accessories aM CYLINDRICAL FUSE-LINKS Catalog Numbers, Ratings - aM (Optional Blown-Fuse Indicator) SIZE (mm x mm) 15519-G 8 x 31 16535-G 10 X 38 17535-G 14 X 51 22 x 58 18555-G RATED In CURRENT (A) RATED VOLTAGE 1 2 4 6 8 10 400V 0.16 0.25 0.5 1 2 4 6 8 10 12 16 20 25 500V 0.25 0.5 1 2 4 6 8 10 12 16 20 25 32 40 45 50 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 400V 690V 500V 400V 690V 500V 400V CATALOG NUMBER w/o Indicator w/Indicator INTERRUPTING RATING (A) 15511-G 15513-G 15519-G 15523-G 15527-G 15531-G - 20,000 16503-G 16507-G 16509-G 16511-G 16513-G 16519-G 16523-G 16527-G 16531-G 16533-G 16535-G 16537-G 16539-G 16711-G 16713-G 16719-G 16723-G 16727-G 16731-G 16733-G 16735-G 16737-G 16739-G 120,000 17507-G 17509-G 17511-G 17513-G 17519-G 17523-G 17527-G 17531-G 17533-G 17535-G 17537-G 17539-G 17543-G 17547-G 17549-G 17551-G 17711-G 17713-G 17719-G 17723-G 17727-G 17731-G 17733-G 17735-G 17737-G 17739-G 17743-G 17747-G 17749-G 17751-G 80,000 18519-G 18523-G 18527-G 18531-G 18533-G 18535-G 18537-G 18539-G 18543-G 18547-G 18551-G 18555-G 18559-G 18563-G 18565-G 18719-G 18723-G 18727-G 18731-G 18733-G 18735-G 18737-G 18739-G 18743-G 18747-G 18751-G 18755-G 18759-G 18763-G 18765-G STANDARD PACK/CTN. 10/100 10/100 10/50 120,000 80,000 10/50 120,000 Blown-Fuse Indicator Dimensions BEFORE AFTER F8 FUSE SIZE A B C 8 x 31 10 x 38 14 x 51 22 x 58 8.5 10.3 14.3 22.2 31.5 38 51 58 6.3 10.5 13.8 16.2 EURO/IEC Fuses & Accessories aM CYLINDRICAL FUSE-LINKS Catalog Numbers, Ratings - aM with Striker SIZE (mm x mm) 17947-G 14 X 51 18951-G Striker 22 X 58 AFTER BEFORE RATED In CURRENT (A) RATED VOLTAGE CATALOG NUMBER INTERRUPTING RATING (A) 1 2 4 6 8 10 12 16 20 25 32 40 45 50 500V 17911-G 17913-G 17919-G 17923-G 17927-G 17931-G 17933-G 17935-G 17937-G 17939-G 17943-G 17947-G 17949-G 17951-G 120,000 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 690V 18919-G 18923-G 18927-G 18931-G 18933-G 18935-G 18937-G 18939-G 18943-G 18947-G 18951-G 18955-G 18959-G 18963-G 18965-G 80,000 400V 500V 400V STANDARD PACK/CTN. 10/50 10/50 120,000 Dimensions FUSE SIZE A B C D E 14 x 51 22 x 58 14.3 22.2 51 58 13.8 16.2 7.5 7.5 3.8 3.8 Peak Let-Thru Current Data - 1-125 Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time - Current Data - 1-125 Amperes Available Current in RMS Symmetrical Amperes Current in Amperes F9 F EURO/IEC Fuses & Accessories aM CYLINDRICAL FUSE-LINKS I2t Characteristics - Discrimination I2t (Ampere2 Seconds) Power Loss (Watts) at Rated Current In RATED In CURRENT (A) SIZE 10 x 38 1 0.1 W 2 0.2 W 4 0.3 W 0.4 W 0.5 W 6 0.4 W 0.5 W 0.6 W 14 x 51 0.3 W 8 0.5 W 0.6 W 0.8 W 10 0.6 W 0.8 W 1.0 W 12 0.7 W 1.0 W 1.2 W 16 0.8 W 1.2 W 1.5 W 20 1.2 W 1.5 W 1.8 W 25 1.6 W 1.9 W 2.0 W 32 2.0 W 2.3 W 2.6 W 40 2.6 W 3.2 W 50 2.9 W 3.9 W 63 Fuse-link In (A) _ _ _ _ _690V _ _ _ _ _ 500V _ _ _ _ _ 400V 22 x 58 4.7 W 80 5.9 W 100 6.5 W 125 9.5 W IEC 269-2 10 x 38 14 x 51 22 x 58 NFC 63210 16 A 50 A 100 A UNE 21103 1.2 W 3W 7W These values are much lower than those allowed by the standards. Operating I2t _ _ _ _ _ Pre-arcing I2t Temperature Temperature rise reached by aM fuse-links at In, measured on their upper contact. F 10